Published On Mar 17, 2024
I had a specific problem with the hydraulic control unit on my 4-post lift. The Run Capacitor kept blowing. In this video, I show my process for troubleshooting my problem as well as other common problems like the Start Capacitor or Centrifugal Switch. After showing my troubleshooting steps, I show how to disassemble the unit so you can see how it comes apart and what is inside. Finally I show how I replaced the unit with a new one from Vevor.
Link to YouTube video for the Single-phase AC Motor Wiring: • Double Capacitor Motor Connection | C...
Product Links:
VEVOR 220v, 10 Quart Hydraulic Power Unit: https://www.vevor.com/hydraulic-power...