Published On Jan 7, 2021
If you have further questions on Renishaw probe programming, please contact us at automatedmfg.com
(--CUT FEATURE--)
N1
T14 M6
(--MEASUREMENT--)
T25 M6 (PROBE CALL)
G54 (WORK OFFSET ACTIVE)
G43 H25 (TOOL OFFSET ACTIVE)
G65 P9832 (PROBE ON)
G65 P9810 X0 Y0 F200. (MOVE TO X0 Y0)
G65 P9810 Z-0.5 F200. (MOVE TO Z-0.5)
G65 P9814 D1.20 (I.D. MEASURE FOR 1.20 BORE)
G65 P9810 Z1.0 F200. (MOVE TO Z1.0)
G65 P9833 (PROBE OFF)
G0 G53 Z0 (RAPID TO Z HOME)
#100=#138 (SAVE MEASURED DIAMETER SIZE TO #100)
(--ANALYSIS--)
IF [#100 GT 1.205] GOTO10 (CHECK FOR OVERSIZE)
IF [#100 LT 1.195] GOTO20 (CHECK FOR UNDERSIZE)
GOTO30
N10 (LEAST MATERIAL CONDITION)
#3000=10 (REJECT PART)
N20 (MOST MATERIAL CONDITION)
#[2400+14]=#[2400+14]-[1.20-#100]/2.
GOTO1
N30 (OK!)
T15 M6 (NEXT OPERATION)